Data Center

Data Center

Data Center (DC) is understood as an infrastructure that concentrates many resource components (hardware, software,...) with the function of storing and processing the entire data system with the ability to continuously operate and maintain high stability.

The server room (also known as the server room) is simply understood as a large CPU with its own configuration and operating system that has the function of providing and operating data for a computer network (company, office,...)

Basic requirements in Data Center design

  • The Datacenter must have access to design, design, administration, construction, handover, and operation according to Tier 3 TIA-942 standard , tối thiểu là mức tier 2.
  • The data center must be designed in a modular form, khả năng mở rộng dễ dàng, the equipment proposed to be equipped and used in the datacenter is not outdated in technology. at least within the next 5 years.
  • A datacenter must be designed and built with full functionality, including a refrigeration system, power supply system, network and backbone system, fire protection system, material access management system, environmental management system, liquid leak development system, centralized management system of all components contained in or related to the datacenter, raised floor system, generator system, and so on. 
  • Data center criteria: Safety, Ease of deployment, Energy saving, High reliability, Easy maintenance, and upgrade 

In the construction of data centers, with its team of experienced experts, Global will offer total solutions that meet the technical standards and actual conditions of customers.

Standards for data centers
Every organization needs an Information Technology Information center, also known as a data center, to manage all available information at all times. It can be created specifically. In addition, each organization can have a disaster recovery site (DR Site) backup center to use in case the main site has any disaster damage issues.

Mesh structure made of matte aluminum 

Aluminum Grid Fog System for Data Centers Tate Grid is a translucent structural solution for hanging large indoor equipment instead of traditional support devices.

Main function

  • Installation is quick and easy compared to traditional installation systems.
  • The area of the grid can be selected according to the needs of each project.
  • Reduce the variety of equipment in the assembly of installations.

Main function
• Directaire board can handle loads ranging from 0 to 22kW. 
• Failure prevention: if there is a failure, the plate is completely opened. 
• SnMP and TCI/IP communications are supported. 
• User can set temperature.
• There are 12 compartments to adjust the openings.
• There are four adjustment zones ranging from 0% to 100%. 
• It responds quickly to temperature changes. 
• The highest temperature that can be displayed on the screen. 
• Dependable in its work The circuit can be switched automatically at N+1 from 2 sources.

Automatic air mass lifting platform - SmartAire Tate

Airflow management for data centers

SmartAire® MZ is an automatic airflow regulator designed for data center applications that can operate in four zones independently of heat. As equipment changes in the rack, the SmartAire MZ plate automatically adjusts the air supply balance.

When compared to conventional raised floor perforated panels, SmartAire® MZ IT load times increase. The air volume cannot be adjusted enough to accommodate the increased load. Therefore, the introduction of SmartAire MZ panels was adopted as an alternative to this problem.