Data Center (DC) is understood as an infrastructure that concentrates many resource components (hardware, software,...) with the function of storing and processing the entire data system with the ability to continuously operate and maintain high stability.

The server room (also known as the server room) is simply understood as a large CPU with its own configuration and operating system that has the function of providing and operating data for a computer network (company, office,...)

Basic requirements in Data Center design

  • The Data Center must be approached in design, construction, management, construction, handover, and operation according to the UPTIME INSTITUTE standards at Tier III and Tier IV levels.
  • The data center must be designed in a modular form, easily expandable, and the proposed equipment installed and used in the data center should not be technologically outdated for at least the next tiếp theo.
  • The Data Center must be designed and constructed with all the functions such as the cooling system, power supply system, uninterruptible power supply system, network and backbone system, fire detection and suppression system, physical access management system, environmental management system, liquid leakage detection and management system, centralized management system for all components within or related to the Data Center, raised floor system, generator system,...
  • Data center criteria: Safety, Ease of deployment, Energy saving, High reliability, Easy maintenance, and upgrade 

In the construction of data centers, with its team of experienced experts, Global will offer total solutions that meet the technical standards and actual conditions of customers.

Standards for data centers
Every organization needs an Information Technology Information center, also known as a data center, to manage all available information at all times. It can be created specifically. In addition, each organization can have a disaster recovery site (DR Site) backup center to use in case the main site has any disaster damage issues.

Mesh structure made of matte aluminum 

Aluminum Grid Fog System for Data Centers Tate Grid is a translucent structural solution for hanging large indoor equipment instead of traditional support devices.

Main function

  • Installation is quick and easy compared to traditional installation systems.
  • The area of the grid can be selected according to the needs of each project.
  • Reduce the variety of equipment in the assembly of installations.

Main function
• Directaire board can handle loads ranging from 0 to 22kW. 
• Failure prevention: if there is a failure, the plate is completely opened. 
• SnMP and TCI/IP communications are supported. 
• User can set temperature.
• There are 12 compartments to adjust the openings.
• There are four adjustment zones ranging from 0% to 100%. 
• It responds quickly to temperature changes. 
• The highest temperature that can be displayed on the screen. 
• Dependable in its work The circuit can be switched automatically at N+1 from 2 sources.

Automatic air mass lifting platform - SmartAire Tate

Airflow management for data centers

SmartAire® MZ is an automatic airflow regulator designed for data center applications that can operate in four zones independently of heat. As equipment changes in the rack, the SmartAire MZ plate automatically adjusts the air supply balance.

When compared to conventional raised floor perforated panels, SmartAire® MZ IT load times increase. The air volume cannot be adjusted enough to accommodate the increased load. Therefore, the introduction of SmartAire MZ panels was adopted as an alternative to this problem.