{"id":965,"date":"2021-08-12T20:43:53","date_gmt":"2021-08-12T20:43:53","guid":{"rendered":"https:\/\/toancau.vn\/?p=965"},"modified":"2025-04-17T09:41:08","modified_gmt":"2025-04-17T09:41:08","slug":"bao-tri-va-lap-dat-he-thong-chong-set","status":"publish","type":"post","link":"https:\/\/toancau.vn\/en\/blog\/bao-tri-va-lap-dat-he-thong-chong-set.html","title":{"rendered":"MAINTENANCE AND INSTALLATION OF SURFACE RESISTANCE SYSTEMS"},"content":{"rendered":"<p>&nbsp;<\/p>\n<p><span style=\"color: #000000;\"><img decoding=\"async\" class=\"size-full wp-image-4114 alignright\" src=\"https:\/\/toancau.vn\/wp-content\/uploads\/2021\/08\/chongset-2.jpg\" alt=\"\" width=\"204\" height=\"133\" srcset=\"https:\/\/toancau.vn\/wp-content\/uploads\/2021\/08\/chongset-2.jpg 204w, https:\/\/toancau.vn\/wp-content\/uploads\/2021\/08\/chongset-2-18x12.jpg 18w\" sizes=\"(max-width: 204px) 100vw, 204px\" \/>Lightning is one of the natural disasters that can cause death and serious property damage. It is worth noting that not all works are protected by lightning protection systems, or that they are protected but not properly according to lightning protection system specifications. And when installing a lightning protection system, most people subjectively think that it is protected, but few people think that even a small unintentional error of the device due to long-term use will also cause great consequences if there is a lightning strike. Therefore, it is extremely important to design and periodically test a lightning protection system.<\/span><\/p>\n<div id=\"toc_container\" class=\"no_bullets\"><p class=\"toc_title\">Table of Contents<\/p><ul class=\"toc_list\"><li><a href=\"#Quy_dinh_bao_tri_he_thong_chong_set\"><span class=\"toc_number toc_depth_1\">1<\/span> Regulations on maintenance of lightning protection systems<\/a><\/li><li><a href=\"#Nguyen_tac_bao_ve_co_ban_cua_mot_he_thong_chong_set_la_de_ngan_chan_nang_luong_cua_set_anh_huong_den_cac_thiet_bi_dien_tu_De_dat_duoc_dieu_nay_he_thong_chong_set_can_phai\"><span class=\"toc_number toc_depth_1\">2<\/span> The basic protection principle of a lightning protection system is to prevent the energy of lightning from affecting electronic equipment. To achieve this, the lightning protection system needs to:<\/a><\/li><li><a href=\"#Quy_dinh_lap_dat_he_thong_chong_set\"><span class=\"toc_number toc_depth_1\">3<\/span> Regulations on the Installation of lightning protection system<\/a><ul><li><a href=\"#a_He_thong_tiep_dia_he_thong_tiep_dat\"><span class=\"toc_number toc_depth_2\">3.1<\/span> a\/ Earthing system (grounding system)<\/a><\/li><li><a href=\"#b_Thi_cong_he_thong_chong_set_truc_tiep\"><span class=\"toc_number toc_depth_2\">3.2<\/span> b\/ Construction of direct lightning protection system<\/a><\/li><li><a href=\"#c_Thi_cong_he_thong_chong_set_lan_truyen\"><span class=\"toc_number toc_depth_2\">3.3<\/span> c\/ Construction of a lightning protection system<\/a><\/li><\/ul><\/li><\/ul><\/div>\n<h2><span id=\"Quy_dinh_bao_tri_he_thong_chong_set\"><span style=\"color: #0000ff;\"><strong>Regulations on maintenance of lightning protection systems<\/strong><\/span><\/span><\/h2>\n<p><span style=\"color: #000000;\">Maintenance and inspection of lightning protection systems should be carried out regularly, at least once a year before the thunderstorm season; it is necessary to check, repair, and replace lightning protection devices that have reduced lightning cutting capacity, measure the grounding resistance, and take remedial measures if the resistance of the grounding system is no longer satisfactory.<\/span><\/p>\n<p><span style=\"color: #000000;\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-3546 aligncenter\" src=\"https:\/\/toancau.vn\/wp-content\/uploads\/2022\/09\/cs3-300x297.jpg\" alt=\"\" width=\"338\" height=\"335\" srcset=\"https:\/\/toancau.vn\/wp-content\/uploads\/2022\/09\/cs3-300x297.jpg 300w, https:\/\/toancau.vn\/wp-content\/uploads\/2022\/09\/cs3-150x150.jpg 150w, https:\/\/toancau.vn\/wp-content\/uploads\/2022\/09\/cs3-12x12.jpg 12w, https:\/\/toancau.vn\/wp-content\/uploads\/2022\/09\/cs3.jpg 450w\" sizes=\"(max-width: 338px) 100vw, 338px\" \/><\/span><\/p>\n<h2><span id=\"Nguyen_tac_bao_ve_co_ban_cua_mot_he_thong_chong_set_la_de_ngan_chan_nang_luong_cua_set_anh_huong_den_cac_thiet_bi_dien_tu_De_dat_duoc_dieu_nay_he_thong_chong_set_can_phai\"><strong><span style=\"color: #000000;\">The basic protection principle of a lightning protection system is to prevent the energy of lightning from affecting electronic equipment. To achieve this, the lightning protection system needs to:<\/span><\/strong><\/span><\/h2>\n<p><span style=\"color: #000000;\">\u2013 Determine the lightning current and the channels (locations) through which the lightning is most likely to hit the ground (avoid the vicinity of sensitive electronic equipment)<\/span><br \/>\n<span style=\"color: #000000;\">\u2013 There is a harmonious coordination between the grounding system and the surge arrester.<\/span><br \/>\n<span style=\"color: #000000;\">\u2013 Depending on the needs of the user, there is a choice to install direct or transmitted lightning protection devices.<\/span><br \/>\n<span style=\"color: #000000;\">\u2013 Lightning rod does not rust and has high sensitivity.<\/span><br \/>\n<span style=\"color: #000000;\">\u2013 Conductor is designed to transmit lightning to the ground.<\/span><br \/>\n<span style=\"color: #000000;\">\u2013 The grounding system is guaranteed.<\/span><\/p>\n<h2><span id=\"Quy_dinh_lap_dat_he_thong_chong_set\"><strong><span style=\"color: #0000ff;\">Regulations on the Installation of lightning protection system<\/span><\/strong><\/span><\/h2>\n<h3><span id=\"a_He_thong_tiep_dia_he_thong_tiep_dat\"><span style=\"color: #000000;\"><strong>a\/ Earthing system (grounding system)<\/strong><\/span><\/span><\/h3>\n<p><span style=\"color: #000000;\">\u2013 Before construction and installation of lightning protection equipment (direct lightning protection and surge protection), it is necessary to consider and check the lightning protection grounding system.<\/span><\/p>\n<p><span style=\"color: #000000;\"><img decoding=\"async\" class=\"wp-image-2828 aligncenter\" src=\"https:\/\/toancau.vn\/wp-content\/uploads\/2021\/08\/tiep-dat-chong-set-300x180.jpg\" alt=\"\" width=\"325\" height=\"195\" srcset=\"https:\/\/toancau.vn\/wp-content\/uploads\/2021\/08\/tiep-dat-chong-set-300x180.jpg 300w, https:\/\/toancau.vn\/wp-content\/uploads\/2021\/08\/tiep-dat-chong-set-18x12.jpg 18w, https:\/\/toancau.vn\/wp-content\/uploads\/2021\/08\/tiep-dat-chong-set.jpg 600w\" sizes=\"(max-width: 325px) 100vw, 325px\" \/><\/span><\/p>\n<h3><span id=\"b_Thi_cong_he_thong_chong_set_truc_tiep\"><strong><span style=\"color: #000000;\">b\/ Construction of direct lightning protection system<\/span><\/strong><\/span><\/h3>\n<p><span style=\"color: #000000;\">\u2013 Air-termination terminals must be installed according to the installation manual..<\/span><br \/>\n<span style=\"color: #000000;\">\u2013 The lightning cable must be firmly clamped.<\/span><br \/>\n<span style=\"color: #000000;\">\u2013 The lightning protection grounding resistance of the direct lightning protection system must be less than the required value.<\/span><br \/>\n<span style=\"color: #000000;\">\u2013 Do not erect lightning rods during thunderstorms or thunder; do not work on roofs or in areas where lightning rods, support posts, or lightning cables may come into contact.\u00a0<\/span><br \/>\n<span style=\"color: #000000;\">\u2013 Labeling the warning.<\/span><\/p>\n<h3><span id=\"c_Thi_cong_he_thong_chong_set_lan_truyen\"><strong><span style=\"color: #000000;\">c\/ Construction of a lightning protection system<\/span><\/strong><\/span><\/h3>\n<p><span style=\"color: #000000;\">\u2013 Before installation, check the type of lightning protection device, connection diagram, and electrical network parameters to ensure that the equipment is installed in accordance with the manufacturer's regulations.<\/span><br \/>\n<span style=\"color: #000000;\">\u2013 Lightning arresters should be installed by professional technicians.<\/span><br \/>\n<span style=\"color: #000000;\">\u2013 The grounding resistor for lightning protection equipment must ensure lightning protection standards.<\/span><br \/>\n<span style=\"color: #000000;\">\u2013 Do not bring the power supply to the arrester when there is no neutral or ground connection.<\/span><\/p>\n<blockquote><p><span style=\"color: #000000;\"><em>If you detect any technical errors or some parts of the system are damaged, please contact lightning protection companies for replacement, maintenance, and repair to ensure the best safety for your health. your family and the people around you.<\/em><\/span><\/p><\/blockquote>","protected":false},"excerpt":{"rendered":"<p>&nbsp; S\u00e9t l\u00e0 m\u1ed9t trong nh\u1eefng thi\u00ean tai c\u00f3 th\u1ec3 g\u00e2y ch\u1ebft ng\u01b0\u1eddi v\u00e0 l\u00e0m thi\u1ec7t h\u1ea1i t\u00e0i s\u1ea3n nghi\u00eam tr\u1ecdng. \u0110i\u1ec1u \u0111\u00e1ng n\u00f3i l\u00e0 kh\u00f4ng ph\u1ea3i b\u1ea5t k\u1ef3 c\u00f4ng tr\u00ecnh n\u00e0o c\u0169ng \u0111\u01b0\u1ee3c b\u1ea3o v\u1ec7 b\u1edfi h\u1ec7 th\u1ed1ng ch\u1ed1ng s\u00e9t ho\u1eb7c \u0111\u01b0\u1ee3c b\u1ea3o v\u1ec7 nh\u01b0ng l\u1ea1i ch\u01b0a \u0111\u00fang quy c\u00e1ch c\u1ee7a m\u1ed9t h\u1ec7 th\u1ed1ng [&hellip;]<\/p>","protected":false},"author":3,"featured_media":4116,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"rank_math_lock_modified_date":false,"footnotes":""},"categories":[16,7],"tags":[],"class_list":["post-965","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-tin-tuc-su-kien"],"acf":[],"_links":{"self":[{"href":"https:\/\/toancau.vn\/en\/wp-json\/wp\/v2\/posts\/965","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/toancau.vn\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/toancau.vn\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/toancau.vn\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/toancau.vn\/en\/wp-json\/wp\/v2\/comments?post=965"}],"version-history":[{"count":2,"href":"https:\/\/toancau.vn\/en\/wp-json\/wp\/v2\/posts\/965\/revisions"}],"predecessor-version":[{"id":8503,"href":"https:\/\/toancau.vn\/en\/wp-json\/wp\/v2\/posts\/965\/revisions\/8503"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/toancau.vn\/en\/wp-json\/wp\/v2\/media\/4116"}],"wp:attachment":[{"href":"https:\/\/toancau.vn\/en\/wp-json\/wp\/v2\/media?parent=965"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/toancau.vn\/en\/wp-json\/wp\/v2\/categories?post=965"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/toancau.vn\/en\/wp-json\/wp\/v2\/tags?post=965"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}